한국어

 
Deutsch  English  Français  Español  Italiano   USA/Canada  Great Britain / Ireland  Australia  South Korea  PR of China

Capacitive Level Measurement Systems (KFS / KFA / KFX)

Logo KFS

The Capacitive Level Measurement Systems (KFS/KFA/KFX) operate according to the three-electrode principle. With this principle the container or an additional electrode serve as a counter-electrode to the probe electrodes. For this reason it is necessary with this system that the container is of a conductive material or a "substitute electrode" is fixed to the container wall, e.g. copper foil. These systems are available with probes for analogue filling level measurement or for detection up to 4 measuring points. The position of the switching points and the analogue measuring area is custom made within the possible effective range and therefore it can be determined for optimized matching of each application. Level measurements of bulk material, liquids or pastes are possible with a dielectric constant as of Er 1,1.

logo_prelevel.jpg

KFS Sensoren

Housing:
Ø 16 mm / Ø 20 mm

Probe length:
max. 2000 mm

Operating voltage:
24 VDC to 250 VAC

Switching points:
1 to 4 or analogue

Housing material:
stainless steel / PTFE
PEEK / PVDF

Permitted ambient temperature:
- 70°C to + 250°C


More information